346 research outputs found

    Evidence for the intrinsically nonlinear nature of receptive fields in vision

    Get PDF
    The responses of visual neurons, as well as visual perception phenomena in general, are highly nonlinear functions of the visual input, while most vision models are grounded on the notion of a linear receptive field (RF). The linear RF has a number of inherent problems: it changes with the input, it presupposes a set of basis functions for the visual system, and it conflicts with recent studies on dendritic computations. Here we propose to model the RF in a nonlinear manner, introducing the intrinsically nonlinear receptive field (INRF). Apart from being more physiologically plausible and embodying the efficient representation principle, the INRF has a key property of wide-ranging implications: for several vision science phenomena where a linear RF must vary with the input in order to predict responses, the INRF can remain constant under different stimuli. We also prove that Artificial Neural Networks with INRF modules instead of linear filters have a remarkably improved performance and better emulate basic human perception. Our results suggest a change of paradigm for vision science as well as for artificial intelligence

    SARS-CoV-2 susceptibility and COVID-19 disease severity are associated with genetic variants affecting gene expression in a variety of tissues

    Get PDF
    Variability in SARS-CoV-2 susceptibility and COVID-19 disease severity between individuals is partly due to genetic factors. Here, we identify 4 genomic loci with suggestive associations for SARS-CoV-2 susceptibility and 19 for COVID-19 disease severity. Four of these 23 loci likely have an ethnicity-specific component. Genome-wide association study (GWAS) signals in 11 loci colocalize with expression quantitative trait loci (eQTLs) associated with the expression of 20 genes in 62 tissues/cell types (range: 1:43 tissues/gene), including lung, brain, heart, muscle, and skin as well as the digestive system and immune system. We perform genetic fine mapping to compute 99% credible SNP sets, which identify 10 GWAS loci that have eight or fewer SNPs in the credible set, including three loci with one single likely causal SNP. Our study suggests that the diverse symptoms and disease severity of COVID-19 observed between individuals is associated with variants across the genome, affecting gene expression levels in a wide variety of tissue types

    Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome : Insights from the LUNG SAFE study

    Get PDF
    Publisher Copyright: © 2020 The Author(s). Copyright: Copyright 2020 Elsevier B.V., All rights reserved.Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55-100 mmHg) patients (P = 0.47). Conclusions: Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort. Trial registration: LUNG-SAFE is registered with ClinicalTrials.gov, NCT02010073publishersversionPeer reviewe

    Mortality and pulmonary complications in patients undergoing surgery with perioperative SARS-CoV-2 infection: an international cohort study

    Get PDF
    Background: The impact of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) on postoperative recovery needs to be understood to inform clinical decision making during and after the COVID-19 pandemic. This study reports 30-day mortality and pulmonary complication rates in patients with perioperative SARS-CoV-2 infection. Methods: This international, multicentre, cohort study at 235 hospitals in 24 countries included all patients undergoing surgery who had SARS-CoV-2 infection confirmed within 7 days before or 30 days after surgery. The primary outcome measure was 30-day postoperative mortality and was assessed in all enrolled patients. The main secondary outcome measure was pulmonary complications, defined as pneumonia, acute respiratory distress syndrome, or unexpected postoperative ventilation. Findings: This analysis includes 1128 patients who had surgery between Jan 1 and March 31, 2020, of whom 835 (74·0%) had emergency surgery and 280 (24·8%) had elective surgery. SARS-CoV-2 infection was confirmed preoperatively in 294 (26·1%) patients. 30-day mortality was 23·8% (268 of 1128). Pulmonary complications occurred in 577 (51·2%) of 1128 patients; 30-day mortality in these patients was 38·0% (219 of 577), accounting for 81·7% (219 of 268) of all deaths. In adjusted analyses, 30-day mortality was associated with male sex (odds ratio 1·75 [95% CI 1·28–2·40], p\textless0·0001), age 70 years or older versus younger than 70 years (2·30 [1·65–3·22], p\textless0·0001), American Society of Anesthesiologists grades 3–5 versus grades 1–2 (2·35 [1·57–3·53], p\textless0·0001), malignant versus benign or obstetric diagnosis (1·55 [1·01–2·39], p=0·046), emergency versus elective surgery (1·67 [1·06–2·63], p=0·026), and major versus minor surgery (1·52 [1·01–2·31], p=0·047). Interpretation: Postoperative pulmonary complications occur in half of patients with perioperative SARS-CoV-2 infection and are associated with high mortality. Thresholds for surgery during the COVID-19 pandemic should be higher than during normal practice, particularly in men aged 70 years and older. Consideration should be given for postponing non-urgent procedures and promoting non-operative treatment to delay or avoid the need for surgery. Funding: National Institute for Health Research (NIHR), Association of Coloproctology of Great Britain and Ireland, Bowel and Cancer Research, Bowel Disease Research Foundation, Association of Upper Gastrointestinal Surgeons, British Association of Surgical Oncology, British Gynaecological Cancer Society, European Society of Coloproctology, NIHR Academy, Sarcoma UK, Vascular Society for Great Britain and Ireland, and Yorkshire Cancer Research

    A first update on mapping the human genetic architecture of COVID-19

    Get PDF
    peer reviewe

    Searches for rare B-s(0) and B-0 decays into four muons

    Get PDF
    Searches for rare Bs0B_s^0 and B0B^0 decays into four muons are performed using proton-proton collision data recorded by the LHCb experiment, corresponding to an integrated luminosity of 9 fb1\text{fb}^{-1}. Direct decays and decays via light scalar and J/ψJ/\psi resonances are considered. No evidence for the six decays searched for is found and upper limits at the 95% confidence level on their branching fractions ranging between 1.8×10101.8\times10^{-10} and 2.6×1092.6\times10^{-9} are set

    Search for the doubly charmed baryon Ξ cc + in the Ξ c + π − π + final state

    Get PDF
    Abstract: A search for the doubly charmed baryon Ξcc+ is performed in the Ξc+π−π+ invariant-mass spectrum, where the Ξc+ baryon is reconstructed in the pK−π+ final state. The study uses proton-proton collision data collected with the LHCb detector at a centre- of-mass energy of 13 TeV, corresponding to a total integrated luminosity of 5.4 fb−1. No significant signal is observed in the invariant-mass range of 3.4–3.8 GeV/c2. Upper limits are set on the ratio of branching fractions multiplied by the production cross-section with respect to the Ξcc++→ (Ξc+→ pK−π+)π+ decay for different Ξcc+ mass and lifetime hypotheses in the rapidity range from 2.0 to 4.5 and the transverse momentum range from 2.5 to 25 GeV/c. The results from this search are combined with a previously published search for the Ξcc+→Λc+K−π+ decay mode, yielding a maximum local significance of 4.0 standard deviations around the mass of 3620 MeV/c2, including systematic uncertainties. Taking into account the look-elsewhere effect in the 3.5–3.7 GeV/c2 mass window, the combined global significance is 2.9 standard deviations including systematic uncertainties

    Contrast Sensitivity Functions in Autoencoders

    Get PDF
    Three decades ago, Atick et al. suggested that human frequency sensitivity may emerge from the enhancement required for a more efficient analysis of retinal images. Here we reassess the relevance of low-level vision tasks in the explanation of the Contrast Sensitivity Functions (CSFs) in light of (1) the current trend of using artificial neural networks for studying vision, and (2) the current knowledge of retinal image representations. As a first contribution, we show that a very popular type of convolutional neural networks (CNNs), called autoencoders, may develop human-like CSFs in the spatio-temporal and chromatic dimensions when trained to perform some basic low-level vision tasks (like retinal noise and optical blur removal), but not others (like chromatic adaptation) or pure reconstruction after simple bottlenecks). As an illustrative example, the best CNN (in the considered set of simple architectures for enhancement of the retinal signal) reproduces the CSFs with an RMSE error of 11\% of the maximum sensitivity. As a second contribution, we provide experimental evidence of the fact that, for some functional goals (at low abstraction level), deeper CNNs that are better in reaching the quantitative goal are actually worse in replicating human-like phenomena (such as the CSFs). This low-level result (for the explored networks) is not necessarily in contradiction with other works that report advantages of deeper nets in modeling higher-level vision goals. However, in line with a growing body of literature, our results suggests another word of caution about CNNs in vision science since the use of simplified units or unrealistic architectures in goal optimization may be a limitation for the modeling and understanding of human vision

    Contrast sensitivity functions in autoencoders

    No full text
    Three decades ago, Atick et al. suggested that human frequency sensitivity may emerge from the enhancement required for a more efficient analysis of retinal images. Here we reassess the relevance of low-level vision tasks in the explanation of the contrast sensitivity functions (CSFs) in light of 1) the current trend of using artificial neural networks for studying vision, and 2) the current knowledge of retinal image representations. As a first contribution, we show that a very popular type of convolutional neural networks (CNNs), called autoencoders, may develop human-like CSFs in the spatiotemporal and chromatic dimensions when trained to perform some basic low-level vision tasks (like retinal noise and optical blur removal), but not others (like chromatic) adaptation or pure reconstruction after simple bottlenecks). As an illustrative example, the best CNN (in the considered set of simple architectures for enhancement of the retinal signal) reproduces the CSFs with a root mean square error of 11% of the maximum sensitivity. As a second contribution, we provide experimental evidence of the fact that, for some functional goals (at low abstraction level), deeper CNNs that are better in reaching the quantitative goal are actually worse in replicating human-like phenomena (such as the CSFs). This low-level result (for the explored networks) is not necessarily in contradiction with other works that report advantages of deeper nets in modeling higher level vision goals. However, in line with a growing body of literature, our results suggests another word of caution about CNNs in vision science because the use of simplified units or unrealistic architectures in goal optimization may be a limitation for the modeling and understanding of human vision.Partially funded by these grants from GVA/AEI/FEDER/EU: MICINN DPI2017- 89867-C2-2-R, MICINN PID2020-118071GB-I00, and GVA Grisolía-P/2019/035 (for JM and QL), and MICINN PGC2018-099651-B-I00 (for A.G.V. and M.B.)

    On the synthesis of visual illusions using deep generative models

    No full text
    Visual illusions expand our understanding of the visual system by imposing constraints in the models in two different ways: i) visual illusions for humans should induce equivalent illusions in the model, and ii) illusions synthesized from the model should be compelling for human viewers too. These constraints are alternative strategies to find good vision models. Following the first research strategy, recent studies have shown that artificial neural network architectures also have human-like illusory percepts when stimulated with classical hand-crafted stimuli designed to fool humans. In this work we focus on the second (less explored) strategy: we propose a framework to synthesize new visual illusions using the optimization abilities of current automatic differentiation techniques. The proposed framework can be used with classical vision models as well as with more recent artificial neural network architectures. This framework, validated by psychophysical experiments, can be used to study the difference between a vision model and the actual human perception and to optimize the vision model to decrease this difference
    corecore